Structural bracing requires a 50 year durability according to the NZBC B2/AS1, Table 1. ETERPAN with a finish (such as ETERPAN Base SEALED) has received a 50 year durability from BRANZ, even when fully exposed. Download here the Eterpan Bracing Manual and BRANZ Durability Report on Eterpan
1) The Rigid Air Barrier is the most common direct fix method used to obtain barcing resistance. Use in combination with our fire and acoustic resistant systems if required. For 4.5 mm thick eterpan BASE as Rigid Air Barrier
| Bracing |
unit (BU/m) |
Brace length |
Eterpan |
Wind load |
Remarks |
Specimen |
Brace |
| Wind |
E/quake |
(mm) |
thick (mm) |
(Pa) |
|
|
code |
| 108 |
98 |
1200 |
4.5 |
< 2,700 |
Concrete floor |
2 |
BR45.12.1C |
| 94 |
80 |
1200 |
4.5 |
< 2,700 |
Timber floor |
4,5,6 |
BR45.12.2T |
| 113 |
100 |
2400 plus |
4.5 |
< 2,700 |
Concrete floor |
7,8 |
BR45.24.1C |
| 104 |
87 |
2400 plus |
4.5 |
< 2,700 |
Timber floor |
9,10 |
BR45.24.1T |
2) For 6.0 and 9.0 mm thick eterpan BASE
| Bracing |
unit(BU/m) |
Brace length |
Eterpan |
Wind load |
Remarks |
Specimen |
Brace |
| Wind |
E/quake |
(mm) |
thick (mm) |
(Pa) |
|
|
code |
| 112 |
122 |
600 |
6.0 |
< 3,700 |
Concrete floor |
11,12 |
BR60.06.1C |
| 125 |
120 |
600 |
6.0 |
< 3,700 |
Timber floor |
13,14 |
BR60.06.2T |
| 150 |
150 |
900-1200 |
6.0 |
< 3,700 |
Timber floor
GIB Braceline |
16 |
BR60.09.2BLT |
| 150 |
150 |
1200 |
6.0 |
< 3,700 |
Timber floor |
18,19,20 |
EB60.12.2T |
| 100 |
98 |
1200-2400 |
6.0 |
< 3,700 |
Timber floor |
ST359 |
BR60.18.1T |
| 100 |
98 |
1200-2400 |
6.0 |
< 3,700 |
Concrete floor |
ST359 |
BR60.18.1C |
| 106 |
102 |
2400 plus |
6.0 |
< 3,700 |
Timber floor |
ST359 |
BR60.24.1T |
| 106 |
102 |
2400 plus |
6.0 |
< 3,700 |
Concrete floor |
ST359 |
BR60.24.1C |
| 112 |
122 |
600 |
7.5 & 9.0 |
< 3,900 |
Concrete floor |
11,12 |
BR75.06.1C |
| 125 |
120 |
600 |
7.5 & 9.0 |
< 3,900 |
Timber floor |
13,14 |
BR75.06.2T |
| 150 |
150 |
900-1200 |
7.5 & 9.0 |
< 3,900 |
Timber floor
GIB Braceline |
16 |
BR75.09.2BLT |
| 150 |
150 |
1200 |
7.5 & 9.0 |
< 3,900 |
Timber floor |
18,19,20 |
BR75.12.2T |
| 100 |
98 |
1200-2400 |
7.5 & 9.0 |
< 3,900 |
Timber floor |
ST359 |
BR75.18.1T |
| 100 |
98 |
1200-2400 |
7.5 & 9.0 |
< 3,900 |
Concrete floor |
ST359 |
BR75.18.1C |
| 106 |
102 |
2400 plus |
7.5 & 9.0 |
< 3,900 |
Timber floor |
ST359 |
BR75.24.1T |
| 106 |
102 |
2400 plus |
7.5 & 9.0 |
< 3,900 |
Concrete floor |
ST359 |
BR75.24.1C |
3) For bracing resistance on cavity systems, please contact us for more information.